Description
Technical Information:
Capacity Cooling kW – 4.95
Capacity (UK) Cooling kW – 4.9
Capacity (T1) Heating kW – 6.0
Power Supply to Unit V/Phase/Hz – 240/1/50
Power supply to – Indoor
Inter connecting Cables – 4*15
cores and rating No. Amps
Running Current Cooling Amps – 6.7
Running Current Heating Amps – 7.2
Power Input Cooling kW – 1.54
Power Input Heating kW – 1.66
Start Current Cooling Amps <7
Start Current Heating Amps – <7
Circuit Breaker Amps – 20
T1 EER Cool (W/W) – 3.31
T1 COP Heat (W/W) – 3.59
ECA compliant – yes
Air Circulation Indoor – (m3/min) – 13
(High Speed) Outdoor – (m3/min) – 41
Sound Levels Indoor – dB(A)+/-3 (at 1.0m) – 32
(High Speed) Outdoor – dB(A)+/-3 (at 1.0m) – 58
Indoor Units WxHxD (mm) – 880 x 260 x 450
Outdoor Units WxHxD (mm) – 870 x 655 x 320
Indoor Units (Kg) – 13
Outdoor Units (Kg) – 60
Liquid (Inch) – 1/4
Suction (Inch) – 1/2
Drain (ID) (mm) – 16
Maximum Elevation (m) – 15
Max. Distance between In & Out (m) – 30
Factory charge (Kg) – 1.2
Charged for — m (m) – 7.5
Additional g/m (g/m) – 20
Capacity Cooling kW – 5.28
Capacity (UK) Cooling kW – 4.8
Capacity (T1) Heating kW – 5.8
Power Supply to Unit V/Phase/Hz – 240/1/50
Power supply to – Indoor
Inter connecting Cables – 4*15
cores and rating No. Amps
Running Current Cooling Amps – 9.03
Running Current Heating Amps – 9.83
Power Input Cooling kW – 1.88
Power Input Heating kW – 2.06
Start Current Cooling Amps – 36.13
Start Current Heating Amps – 36.13
Circuit Breaker Amps – 20
T1 EER Cool (W/W) – 3.31
T1 COP Heat (W/W) – 3.59
ECA compliant – yes
Air Circulation Indoor – (m3/min) – 13
(High Speed) Outdoor – (m3/min) – 58
Sound Levels Indoor – dB(A)+/-3 (at 1.0m) – 32
(High Speed) Outdoor – dB(A)+/-3 (at 1.0m) – 49
Indoor Units WxHxD (mm) – 880 x 260 x 450
Outdoor Units WxHxD (mm) – 870 x 655 x 320
Indoor Units (Kg) – 35
Outdoor Units (Kg) – 52
Liquid (Inch) – 1/4
Suction (Inch) – 1/2
Drain (ID) (mm) – 32
Maximum Elevation (m) – 15
Max. Distance between In & Out (m) – 30
Factory charge (Kg) – 1.3
Charged for — m (m) – 7.5
Additional g/m (g/m) – 35
These air conditioning units must be installed by an F-Gas qualified engineer. ( We will ask to view this certificate before the shipment) We can install the unit for you using our F-Gas Certified Engineers.