Description
Technical Specifications:
RAK-18PSB | |||
Nominal Cooling Capacity | (min-max) | kW | 1.8 (0.5-2.8) |
Sensible Cooling Capacity | kW | 1.8 | |
UK Cooling Capacity (sensible) | kW | 1.9 (1.7) | |
Nominal Heating Capacity | (min-max) | kW | 2.3 (0.6-4.8) |
Nominal Cooling Power Input | (min-max) | kW | 0.300 (0.070-0.880) |
Nominal Heating Power Input | (min-max) | kW | 0.375 (0.065-1.620) |
Seasonal Efficiency | SEER | 7.41 | |
Energy Efficiency Class | A++ | ||
Annual Energy Consumption | kWh/yr | 85 | |
Seasonal Efficiency (Average Climate) | SCOP | 4.6 | |
Energy Efficiency Class | A++ | ||
Annual Energy Consumption | kWh/yr | 588 | |
Nominal Load Efficiency | EER/COP | 6.00/6.13 | |
Energy Class | (cool/heat) | A/A | |
Noise Level Cooling (Sound Pressure) | (SL/L/M/H) | dB(A) | 22/28/34/40 |
Noise Level Heating (Sound Pressure) | (SL/L/M/H) | dB(A) | 22/30/34/41 |
Noise Level (Sound Power) | dB(A) | 54 | |
Air Flow Cooling Mode | (SL/L/M/H) | m³/h | 260/300/420/470 |
Air Flow Heating Mode | (SL/L/M/H) | m³/h | 260/300/420/540 |
Dehumidification | l/hr | 1.2 | |
Dimensions | HxWxD | mm | 295x798x258 |
Weight | kg | 12.0 | |
Power Supply | 230V / 1Ph / 50Hz | ||
Drain Diameter (ext) | Ø16mm | ||
Remote Control | Standard | Infra Red (RAR-5W1) | |
Optional | Wired (SPX-RCDB) | ||
Outdoor Unit | RAC-18WSB | ||
Noise Level Cooling (Sound Pressure) | Night Mode | dB(A) | 46 |
Noise Level Heating (Sound Pressure) | Night Mode | dB(A) | 46 |
Noise Level (Sound Power) | dB(A) | 60 | |
Air Flow (Cooling/Heating) | m³/h | 1860/1620 | |
Dimensions | HxWxD | mm | 600x792x299 |
Weight | kg | 40 | |
Piping Diameter | (Liquid/Gas) | Inch | 1/4 – 1/2 |
mm | 6.35 – 12.70 | ||
Minimum Pipe Length | m | 3.0 | |
Maximum Pipe Length | m | 20 | |
Maximum Height Difference | m | 10 | |
Current Quantity of Refrigerant | kg | 1.35 | |
Chargeless/Additional Refrigerant | m / g/m | 20 / – | |
Power Supply | 230V / 1Ph / 50Hz | ||
Recommended Fuze Size | A | 25 | |
Starting Current | A | 2.32/2.42 | |
Running Current (Cooling/Heating) | A | 0.30-3.83/0.28-7.04 | |
Interconnecting Cables | No. | 3+E | |
Working Range (Cooling/Heating) | °C | -10-43 / -20-21 | |
Refrigerant / GWP | R410A / 1975 | ||
Compressor Type | Scroll |
These air conditioning units must be installed by an F-Gas qualified engineer. ( We will ask to view this certificate before the shipment) We can install the unit for you using our F-Gas Certified Engineers.
Reviews