Description
Key Product Features:
- Decrease of temperature variation by automatic fan speed selection or freely selectable 3-step fan speed.
- Improved comfort as a result of better airflow distribution from the vertical out blow which allows manual adjustment of air outlet blades at the top of the unit.
- Selectable horizontal out blow to better suit the layout of the room (via wired remote controller BRC1E*/BRC1H*)
- Unified indoor unit range for R-32 and R-410A
- Combining with R-32 Bluevolution technology, reduces environmental impact with 68% compared to R-410A, leads directly to lower energy consumption thanks to its high energy efficiency and has up to lower 16% refrigerant charge
Technical Data:
Indoor Unit:
| Casing | Colour | Fresh White | |||
| Control systems | Wired remote control | BRC1H52W/S/K , BRC1E53A , BRC1E53B , BRC1E53C , BRC1D52 | |||
| Dimensions | Unit | Depth | 270 | mm | |
| Height | 1,850 | mm | |||
| Width | 600 | mm | |||
| Fan | Air flow rate | Cooling | High | 18 | m³/min | 
| Medium | 16 | m³/min | |||
| Low | 14 | m³/min | |||
| Heating | High | 18 | m³/min | ||
| Medium | 16 | m³/min | |||
| Low | 14 | m³/min | |||
| Piping connections | Drain | I.D. 20/O.D. 26 | |||
| Gas | OD | 15.9 | mm | ||
| Liquid | OD | 9.52 | mm | ||
| Power supply | Frequency | 50/60 | Hz | ||
| Phase | 1~ | ||||
| 220-240/220 | V | ||||
| Sound power level | Cooling | 55 | dBA | ||
| Sound pressure level | Cooling | High | 43 | dBA | |
| Low | 38 | dBA | |||
| Medium | 41 | dBA | |||
| Heating | High | 43 | dBA | ||
| Medium | 38 | dBA | |||
| Nom. | 41 | dBA | |||
| Weight | Unit | 42 | kg | ||
Outdoor Unit:
| Compressor | Type | Hermetically sealed swing compressor | ||||
| Current | 50Hz | 20 | A | |||
| Dimensions | Unit | Depth | 460 | mm | ||
| Height | 870 | mm | ||||
| Width | 1,100 | mm | ||||
| Operation range | Cooling | Ambient | Min. | -20 | °CDB | |
| Max. | 52 | °CDB | ||||
| Heating | Ambient | Min. | -20 | °CWB | ||
| Max. | 18 | °CWB | ||||
| Piping connections | Additional refrigerant charge | See installation manual | kg/m | |||
| Gas | OD | 15.9 | mm | |||
| Level difference | IU | OU | Max. | 30 | m | |
| IU | Max. | 0.5 | m | |||
| Liquid | OD | 10 | mm | |||
| Piping length | OU | IU | Max. | 55 | m | |
| System | Equivalent | 75 | m | |||
| Chargeless | 40 | m | ||||
| Power supply | Frequency | 50 | Hz | |||
| Phase | 1~ | |||||
| 220-240 | V | |||||
| Refrigerant | Charge | 3.20 | kg | |||
| GWP | 675 | |||||
| Type | R-32 | |||||
| Sound power level | Cooling | 64 | dBA | |||
| Sound pressure level | Cooling | Nom. | 46 | dBA | ||
| Heating | Nom. | 48 | dBA | |||
| Weight | Unit | 81 | kg | |||
These air conditioning units must be installed by an F-Gas qualified engineer. ( We will ask to view this certificate before the shipment) We can install the unit for you using our F-Gas Certified Engineers.
 
	


 
				
Reviews
There are no reviews yet.