Description
Product Key Feature’s:
• High CoP, up to record 3.76
• High Air movement volume
• Fixed wall mounted controller
• Slim construction
• Pipe runs up to 75 meters
• Low noise levels
• Back-up switch for loss of controller
• Cold draft prevention on heat pump start up
• Fault diagnosis
• Auto re-start after power interruption
• PRE-CHARGED WITH REFRIGERANT for up to 30 metres pipe length
Product Technical Data:
Power source 1 ph 240V / 415V ~50Hz
Type Inverter controlled
COOLING (nominal) max. kW 9.1 / 31000 BTU
HEATING (nominal) max. kW 10.00 / 34000 BTU
UK Cooling (max) kW 6.2
UK Sensible cooling kW (max) kW 11.2
E.E.R.
Energy label A++
High SCOP
ECA – Yes
INDOOR UNIT:
| Model | RZASG100M7V1 | ||||
| Casing | Colour | Ivory white | |||
| Material | Painted galvanized steel plate | ||||
| Dimensions | Unit | Height | mm | 990 | |
| Width | mm | 940 | |||
| Depth | mm | 320 | |||
| Packed unit | Height | mm | 1,170 | ||
| Width | mm | 1,015 | |||
| Depth | mm | 422 | |||
| Weight | Unit | kg | 70 | ||
| Packed unit | kg | 78 | |||
| Packing | Weight | kg | 9 | ||
| Heat exchanger | Fin | Type | WF fin | ||
| Treatment | Anti-corrosion treatment (PE) | ||||
| Fan | Type | Propeller | |||
| Discharge direction | Horizontal | ||||
| Quantity | 1 | ||||
| Air flow rate | Cooling | Nom. | m³/min | 69 | |
| Heating | Nom. | m³/min | 82 | ||
| Partial | m³/min | ||||
| Fan motor | Quantity | 1 | |||
| Model | Brushless DC motor | ||||
| Output | W | 200 | |||
| Drive | Direct drive | ||||
| Compressor | Quantity | 1 | |||
| Type | Hermetically sealed swing compressor | ||||
| Operation range | Cooling | Ambient | Min. | °CDB | -15 |
| Max. | °CDB | 46 | |||
| Heating | Ambient | Min. | °CWB | -15 | |
| Max. | °CWB | 15.5 | |||
| Sound power level | Cooling | dBA | 70 | ||
| Heating | dBA | ||||
| Sound pressure level | Cooling | Nom. | dBA | 53 | |
| Heating | Nom. | dBA | 57 | ||
| Refrigerant | Type | R-32 | |||
| Charge | kg | 2.60 | |||
| Charge | TCO2Eq | 1.76 | |||
| Control | Expansion valve (electronic type) | ||||
| GWP | 675 | ||||
| Circuits | Quantity | 1 | |||
| Refrigerant oil | Type | FW68DA | |||
| Charged volume | l | 0.90 | |||
| Piping connections | Liquid | Quantity | 1 | ||
| Type | Flare connection | ||||
| OD | mm | 9.52 | |||
| Gas | Quantity | 1 | |||
| Type | Flare connection | ||||
| OD | mm | 15.9 | |||
| Drain | Quantity | 5 | |||
| Type | Hole | ||||
| OD | mm | 26 | |||
| Piping length | OU – IU | Min. | m | 5 | |
| Max. | m | 50 | |||
| System | Equivalent | m | 70 | ||
| Chargeless | m | 30 | |||
| Additional refrigerant charge | kg/m | See installation manual | |||
| Level difference | IU – OU | Max. | m | 30.0 | |
| IU – IU | Max. | m | 0.5 | ||
| Heat insulation | Both liquid and gas pipes | ||||
| Defrost method | Reversed cycle | ||||
| Defrost control | Sensor for outdoor heat exchanger temperature | ||||
| Capacity control | Method | Inverter controlled | |||
| PED | Category | Category II | |||
| Safety devices | Item | 01 | High pressure switch | ||
| 02 | Low pressure switch | ||||
| 03 | Fan driver overload protector | ||||
| 04 | Fuse | ||||
| 05 | Compressor motor thermal protector | ||||
| Standard Accessories | Tie-wraps | 2 | |||
| Installation manual | 1 | ||||
| Refrigerant label for F-gas regulation | 1 | ||||
| General safety precautions | 1 | ||||
| LOT10 Energy Label | 1 | ||||
| Peel off F-gas label | |||||
| Power supply | Name | V1 | |||
| Phase | 1~ | ||||
| Frequency | Hz | 50 | |||
| Voltage | V | 220-240 | |||
| Voltage range | Min. | V | 198 | ||
| Max. | V | 264 | |||
| Current | Zmax | List | Complies to EN61000-3-11 | ||
| Minimum Ssc value | kVa | Equipment complying with EN / IEC 61000-3-12, See note 2, See note 3 | |||
| Wiring connections | For power supply | Remark | See installation manual outdoor unit | ||
| For connection with indoor | Remark | See installation manual outdoor unit | |||
| Power supply intake | See installation manual outdoor unit | ||||
| Current – 50Hz | Maximum fuse amps (MFA) | A | 25 | ||
| Notes | (1) – According to ENER Lot 21 | ||||
| (2) – European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current larger than 16A and ≤ 75A per phase. | |||||
| (3) – Ssc: Short-circuit power | |||||
| (4) – European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current ≤ 16A per phase. | |||||