Key Product Features:
- Discretely concealed in the ceiling: only the suction and discharge grilles are visible
- Reduced energy consumption thanks to specially developed DC fan motor
- Optional fresh air intake
- Slimmest unit in class, only 245mm (300mm built-in height) and therefore narrow ceiling voids are no longer a challenge
- Medium external static pressure up to 150Pa facilitates using flexible ducts of varying lengths
- Possibility to change ESP via wired remote control allows optimisation of the supply air volume
- Low operation sound level down to 25dBA
- Flexible installation: air suction direction can be altered from rear to bottom suction and choice between free use or connection to optional suction grilles
- Standard built-in drain pump with 625mm lift increases flexibility and installation speed
- Unified indoor unit range for R-32 and R-410A
- Multi zoning kit allows multiple individually-controlled climate zones to be served by one indoor unit
- Combining with R-32 Bluevolution technology, reduces environmental impact with 68% compared to R-410A, leads directly to lower energy consumption thanks to its high energy efficiency and has up to lower 16% refrigerant charge
Technical Data:
| Casing | Colour | Not painted (galvanised) | |||
| Material | Galvanised steel plate | ||||
| Control systems | Infrared remote control | BRC4C65 BRC4C66 | |||
| Wired remote control | BRC1H52W/S/K BRC1E53A BRC1E53B BRC1E53C BRC1D52 | ||||
| Dimensions | Unit | Depth | 800 | mm | |
| Height | 245 | mm | |||
| Width | 1,000 | mm | |||
| Drain-up height | 625 | mm | |||
| Fan | Air flow rate | Cooling | High | 18.0 | m³/min |
| Medium | 15.0 | m³/min | |||
| Low | 12.5 | m³/min | |||
| Heating | High | 18.0 | m³/min | ||
| Medium | 15.0 | m³/min | |||
| Low | 12.5 | m³/min | |||
| External static pressure | High | 150 | Pa | ||
| Nom. | 30 | Pa | |||
| Piping connections | Drain | VP20 (I.D. 20/O.D. 26) | |||
| Gas | OD | 15.90 | mm | ||
| Liquid | OD | 9.52 | mm | ||
| Power supply | Frequency | 50/60 | Hz | ||
| Phase | 1~ | ||||
| Voltage | 220-240/220 | V | |||
| Sound power level | Cooling | 56.0 | dBA | ||
| Sound pressure level | Cooling | High | 30.0 | dBA | |
| Low | 25.0 | dBA | |||
| Medium | 28.0 | dBA | |||
| Heating | High | 31.0 | dBA | ||
| Low | 25.0 | dBA | |||
| Medium | 28.0 | dBA | |||
| Weight | Unit | 35.0 | kg | ||
| Compressor | Type | Hermetically sealed swing compressor | ||||
| Current | 50Hz | Maximum fuse amps (MFA) | 20 | A | ||
| Dimensions | Unit | Depth | 320 | mm | ||
| Height | 770 | mm | ||||
| Width | 900 | mm | ||||
| Operation range | Cooling | Ambient | Min. | -15 | °CDB | |
| Max. | 46 | °CDB | ||||
| Heating | Ambient | Min. | -15 | °CWB | ||
| Max. | 15.5 | °CWB | ||||
| Piping connections | Additional refrigerant charge | See installation manual | kg/m | |||
| Gas | OD | 15.9 | mm | |||
| Level difference | IU | OU | Max. | 30.0 | m | |
| IU | Max. | 0.5 | m | |||
| Liquid | OD | 9.52 | mm | |||
| Piping length | OU | IU | Max. | 50 | m | |
| System | Equivalent | 70 | m | |||
| Chargeless | 30 | m | ||||
| Power supply | Frequency | 50 | Hz | |||
| Phase | 1~ | |||||
| Voltage | 220-240 | V | ||||
| Refrigerant | Charge | 2.45 | kg | |||
| GWP | 675 | |||||
| Type | R-32 | |||||
| Sound power level | Cooling | 65 | dBA | |||
| Sound pressure level | Cooling | Nom. | 46 | dBA | ||
| Heating | Nom. | 47 | dBA | |||
| Weight | Unit | 60 | kg | |||
| Accessories: |
| BRP069C81 Wi-Fi adapter for use with Daikin ONECTA App |
| BRC1H52W Wired touch screen remote controller – White (Included as standard) |
| BRC1H52S Wired touch screen remote controller – Silver |
| BRC1H52K Wired touch screen remote controller – Black |
| BRC4C65 Wireless remote controller |
| K.CGM Condensing unit guard (1150 x 1150 x 650) |
| K.CWB90-2 Wall bracket (90kg, 500mm support arm) |
| K.DT1 Condensate drip tray for use with K.CWB90-2 |
| K.RSS Wireless room mounted temperature sensor and receiver |
| KLIC-DI KNX Interface for Sky Air and VRV systems |
| KRCS01-4 Remote room mounted temperature sensor |
| KRP4A53 and UK.FB2 Unit/group adaptor PCB for remote on/off, statusindication and temperature setting |
| RS-SE Service and configuration tool for K.RSS |
| RTD-10 and UK.FB2 Enhanced function PCB for Sky Air and VRV. Dutyrotation, Lead Lag control and heating interlock |
| RTD-20 and UK.FB2 Energy control PCB for Sky Air and VRV |
| RTD-NET and UK.FB2 Modbus interface PCB for Sky Air and VRV |
| UK.RC2 Return chamber – FBA35-50 – 2X200mm Spg |
| UK.RC3 Return chamber – FBA60-71 – 2X200mm Spg |
| UK.RC3A Return chamber – FBA60-71 – 3X200mm Spg |
| UK.SF2 Supply flange – FBA35-50 – 2×200 Spg |
| UK.SF3 Supply flange – FBA60-71 – 2×200 Spg |
| UK.SF3A Supply flange – FBA60-71 – 3×200 Spg |


Reviews
There are no reviews yet.