Description
Key Product Features:
- Ideal for comfortable air flow in wide rooms thanks to Coanda effect: up to 100° discharge angle
- Even rooms with ceilings up to 3.8m can be heated up or cooled down very easily without capacity loss
- Can easily be installed in both new and refurbishment projects
- Combining with R-32 Bluevolution technology, reduces environmental impact with 68% compared to R-410A, leads directly to lower energy consumption thanks to its high energy efficiency and has up to lower 16% refrigerant charge
- Can easily be mounted in corners and narrow spaces, as it only needs 30mm lateral service space
- Unified indoor unit range for R-32
- Reduced energy consumption thanks to specially developed DC fan motor
- 5 different fan speeds available for maximum comfort
- Stylish unit blends easily with any interior. The flaps close entirely when the unit is not operating and there are no air intake grilles visible
Technical Data:
| 2-1 Technical Specifications | FAA100A+RZASG100MV1 | ||||
| Power input – 50Hz | Cooling | Nom. | kW | 0.061 | |
| Heating | Nom. | kW | 0.061 | ||
| Casing | Colour | Fresh White | |||
| Material | Resin | ||||
| Dimensions | Unit | Height/Width/ Depth | mm | 340/1,200/240 | |
| Packed unit | Height/Width/ Depth | mm | 429/1,310/325 | ||
| Weight | Unit | kg | 17.0 | ||
| Packed unit | kg | 24 | |||
| Heat exchanger | Fin | Type | Cross fin coil (Multi slit fins and Hi-XB tubes) | ||
| Fan | Type | Cross flow fan | |||
| Quantity | 1 | ||||
| Air flow rate | Cooling | High | m³/min | 26.0 | |
| cfm | 918 | ||||
| Mediu m | m³/min | 23 | |||
| cfm | 812 | ||||
| Low | m³/min | 19.0 | |||
| cfm | 671 | ||||
| Heating | High | m³/min | 26.0 | ||
| cfm | 918 | ||||
| Mediu m | m³/min | 23.0 | |||
| cfm | 812 | ||||
| Low | m³/min | 19.0 | |||
| cfm | 671 | ||||
| Fan motor | Speed | Steps | 3 | ||
| Output | High | W | 64 | ||
| Phase x Voltage | V | DC325 | |||
| Full load amps (FLA) | Cooling | A | 0.4 | ||
| Heating | A | 0.4 | |||
| Sound power level | Cooling | dBA | 65 | ||
| Heating | dBA | 65 | |||
| Sound pressure level | Cooling | High/Medium/ Low | dBA | 49/45/41 | |
| Heating | High/Medium/ Low | dBA | 49/45/41 | ||
| Refrigerant | Type | R-410A / R-32 | |||
| Piping connections | Liquid | Type/OD | mm | Flare connection/9,52 | |
| Gas | Type/OD | mm | Flare connection/15.9 | ||
| Drain | VP13 (I.D. 13/O.D. 18) | ||||
| Heat insulation | Foamed polystyrene/polyethylene | ||||
| 2-2 Electrical Specifications | FAA100A | ||||
| Power supply | Phase | 1~ | |||
| Frequency | Hz | 50 | |||
| Voltage | V | 220-240 | |||
These air conditioning units must be installed by an F-Gas qualified engineer. ( We will ask to view this certificate before the shipment) We can install the unit for you using our F-Gas Certified Engineers.


Reviews
There are no reviews yet.