Description
Technical Information:
Nominal Capacity Cooling kW – 14.8
Capacity (UK) Cooling kW – 14
Nominal Capacity (T1) Heating kW – 18.7
Power Supply to Unit V/Phase/Hz – 240/1/50
Power supply to – outdoor
Inter connecting Cables – 4*15
cores and rating No. Amps 5/20
Running Current Cooling Amps – 22.1
Running Current Heating Amps – 23
Power Input Cooling kW – 5.09
Power Input Heating kW – 4.53
Start Current Cooling Amps – <23
Start Current Heating Amps – <23
Circuit Breaker Amps – 50
T1 EER Cool (W/W) – 2.81
T1 COP Heat (W/W) – 3.68
ECA compliant – yes
Air Circulation Indoor – (m3/min) – 44
(High Speed) Outdoor – (m3/min) – 52
Sound Levels Indoor – dB(A)+/-3 (at 1.0m) – 40
(High Speed) Outdoor – dB(A)+/-3 (at 1.0m) – 55
Indoor Units WxHxD (mm) – 1,250 x 360 x 700
Outdoor Units WxHxD (mm) – 950 x 1,380 x 330
Indoor Units (Kg) – 42
Outdoor Units (Kg) – 92
Liquid (Inch) – 3/8
Suction (Inch) – 5/8
Drain (ID) (mm) – 16
Maximum Elevation (m) – 30
Max. Distance between In & Out (m) – 75
Factory charge (Kg) – 3.4
Charged for — m (m) – 7.5
Additional g/m (g/m) – 40
These air conditioning units must be installed by an F-Gas qualified engineer. ( We will ask to view this certificate before the shipment) We can install the unit for you using our F-Gas Certified Engineers.