Description
Technical Specifications:
Indoor Unit Model | rak-18ped | ||
Nominal Cooling Capacity (min – max) | kW | 2.00 (0.90 – 2.50) | |
Sensible Cooling Capacity | kW | 1.99 | |
UK Cooling Capacity (sensible) | kW | 1.9 (1.7) | |
Heating capacity at -7°C | kW | 1.75 | |
Nominal Heating Capacity (min – max) | kW | 2.50 (0.90 – 3.20) | |
Nominal cooling power input (min – max) | kW | 0.58(0.25-1.01) | |
Nominal heating power input (min – max) | kW | 0.62(0.25-0.97) | |
Seasonal Efficiency SEER (4)Energy Efficiency Class Annual Energy Consumption | kWh/yr | 5.80 | |
A+ | |||
121 | |||
Seasonal Efficiency SCOP (4) (Average Climate)Energy Efficiency Class Annual Energy Consumption | kWh/yr | 3.80 | |
A | |||
316 | |||
Nominal Load Efficiency EER / COP (5)Energy Class (Cool/Heat) | 3.45/4.03 | ||
A/A | |||
Noise level cooling (sound pressure) (SL / L / M / H) | (2) | dB(A) | 21/24/33/37 |
Noise level heating (sound pressure) (SL / L / M / H) | (2) | dB(A) | 19/22/33/38 |
Noise level (sound power) (1) | dB(A) | 51 | |
Air flow cooling mode (SL / L / M / H) | m3/h | 312/350/400/440 | |
Air flow heating mode (SL / L / M / H) | m 3/h | 312/350/420/480 | |
Dehumidification | l/h | 1.2 | |
Dimensions (H x W x D) | mm | 280x780x218 | |
Weight | kg | 7.5 | |
Power supply | From Outdoor Unit | ||
Drain diameter (ext) | φ16mm | ||
Remote Control | Std | Infra Red (RAR-5F1) | |
Opt. 1 | Wired (SPX-RCDB) | ||
Opt. 2 | Wired (SPX-WKT2) |
Outdoor Unit Model | rac-18wed | ||
Noise level cooling (sound pressure) (night mode) | (3) | dB(A) | 45 |
Noise level heating (sound pressure) (night mode) | (3) | dB(A) | 46 |
Noise level (sound power) (1) | dB(A) | 59 | |
Air flow (Cooling / Heating) | m3/h | 1860/1620 | |
Dimensions (H x W x D) | mm | 530x660x278 | |
Weight | kg | 24.5 | |
Piping diameter (Liquid / Gas) | Inch | 1/4 – 3/8 | |
mm | 6.35 – 9.52 | ||
Minimum Piping Length | m | 3.0 | |
Maximum Piping L | m | 20/10 | |
Current Quantity of Refrigerant | kg | 0.72 | |
Chargeless / Additional Refrigerant Charge | m / g/m | 20/ – | |
Power supply | 230V/1Ph/50Hz | ||
Recommended fuse size | A | 16 | |
Starting current (cooling/heating) | A | <1 Amp | |
Running current (cooling/heating) | A | 1.09-4.39/1.09-4.22 | |
Interconnecting Cables | No. | 3 + E | |
Working Range (cooling/heating) | °C | -10°C~+43°C / -15°C~+21°C | |
Refrigerant / GWP | R32 / 1975 | ||
Compressor type | Rotary |
These air conditioning units must be installed by an F-Gas qualified engineer. ( We will ask to view this certificate before the shipment) We can install the unit for you using our F-Gas Certified Engineers.